Determination of the Equilibrium Constant, Kc
Virtual spectrophotometry · Iron(III)–thiocyanate complex · Simulated educational measurements
Background Information
Iron(III) ions react reversibly with thiocyanate ions to produce a red complex:
At equilibrium, forward and reverse reactions continue at equal rates. The equilibrium constant is Kc = [FeSCN²⁺] / ([Fe³⁺][SCN⁻]). Concentrations are expressed in mol/L; Kc is reported using the conventional concentration expression.
Beer–Lambert law
Absorbance is approximately proportional to the concentration of the absorbing complex: A = εℓc, where ε is molar absorptivity, ℓ is path length, and c is concentration. A calibration graph of absorbance against known FeSCN²⁺ concentration gives a slope used to determine unknown concentrations.
Preparing standards
Calibration standards are prepared with Fe³⁺ in large excess so that nearly all added SCN⁻ forms FeSCN²⁺. This is an approximation; real procedures may require a more careful calibration treatment.
Equilibrium mixtures and ICE calculations
For each equilibrium mixture, initial concentrations are calculated after dilution. If x = [FeSCN²⁺]eq, then [Fe³⁺]eq = [Fe³⁺]initial − x and [SCN⁻]eq = [SCN⁻]initial − x.
Print or save the assignment, perform the virtual lab, record observations and complete your lab report.
Student Laboratory Assignment
Research question: How can spectrophotometry be used to determine the equilibrium constant for formation of FeSCN²⁺?
- Read the background and write a hypothesis about absorbance versus complex concentration.
- Measure at least four calibration standards with known FeSCN²⁺ concentrations.
- Generate the calibration graph and identify its slope.
- Prepare and measure at least three equilibrium mixtures with different starting concentrations.
- Use the calibration to calculate x, equilibrium concentrations, and Kc for each mixture.
- Calculate mean Kc, explain variations, evaluate limitations, and submit the completed lab report.
Virtual Spectrophotometry Station
1. Calibration standards
Use the virtual spectrophotometer at 447 nm with a 1.00 cm cuvette. The calibration uses a nominal ε of 4,700 L mol⁻¹ cm⁻¹.
2. Equilibrium mixture
Select a solution to begin.
Virtual spectrophotometer
1.00 cm optical path
Data Tables & Calibration Graph
Calibration standards
| Standard | [FeSCN²⁺] (mol/L) | Absorbance |
|---|
Calibration slope: —
Equilibrium trials
| Trial | [Fe³⁺]₀ | [SCN⁻]₀ | A | [FeSCN²⁺]eq | [Fe³⁺]eq | [SCN⁻]eq | Kc |
|---|
Mean Kc: —
Student Laboratory Report
Enter your responses. Text autosaves in this browser. Use Print / Save PDF to submit a copy to your teacher.
Experimental results
Teacher Resources
Learning goals: Describe dynamic equilibrium, apply the Beer–Lambert law, calculate equilibrium concentrations using an ICE approach, and evaluate variation in experimental Kc.
Suggested assessment (KTCA)
| Category | Weight | Evidence |
|---|---|---|
| Knowledge & Understanding | 25% | Equilibrium theory, spectrophotometry |
| Thinking & Investigation | 35% | Trial design, calculations, uncertainty |
| Communication | 20% | Graphs, tables, lab-report clarity |
| Application | 20% | Interpretation and transfer of concepts |
Teacher notes
Nominal model Kc = 140; ε = 4,700 L mol⁻¹ cm⁻¹; path length = 1.00 cm. The simulated data are deliberately simplified. Calibration should use at least two distinct standards, with four or more recommended. The app calculates the through-origin calibration slope using least squares; student estimates therefore vary slightly with the standards selected.
For a physical experiment, consider activity effects, temperature, iron complexation, incomplete standard conversion, instrument blanking, and the distinction between apparent and thermodynamic equilibrium constants. Do not use this simulation as a source of reference Kc values.